Delivery terms
Product will be ordered from supplier. If the supplier is unable to deliver by the specified date, we will inform you by e-mail
Available | Supplier Warehouse |
Pickup in department For free
IMPORTANT: The office will be closed on 10 January 2025 due to an inventory.
Quantity in shop
Not available | Central Warehouse |
Not available | Tallinn Office |
Home delivery
Over €25.00 (Orders up to 1000 kgs) | For free |
To €25.00 (Orders up to 1000 kgs) | €4.50 |
Delivery to DPD pickup locations
€3.50
Product description
The CBIs combine the functions of Power Supply with those of Back Up Module and of Battery Charger. They use switching technology with microcontrollers and optimize the loading and unloading times of the accumulator without a deep discharge, the switching from the battery to the charger without any interruption, automatic protection without fuse against the reserve polarity, short circuit and overload and overvoltage.
They carry out diagnostic checks on the inner battery through the Life Test, enabling the users to select the most appropriate charging curve to maximize the efficiency of the system and to guarantee a long-life battery while intensifying its performances. They are equipped with relays to warn against the power outage and the defective battery. They conform to the most innovative battery management as well as electrical safety standards. They can be mounted on DIN Rails.
Parallel connection is possible.
Specifications:
Model | CBI4810AP |
INPUT | |
Nominal input voltage AC | 115V - 230V - 277V |
Voltage range AC | 90V - 135V; 180V - 305V |
Inrush Current (Vn – In nom. Load) I2t | ≤35A <5ms |
freequency | 47Hz - 63Hz |
Input current (115V - 230V AC) | 9A - 4,5A |
Internal fuse (not replaceable) | 10A |
External fuse (recomended) MCB curve B | 16A |
OUTPUT DATA (internal power supply) | |
Output voltage (Vn) | 48V DC |
Output current (In) | 10A |
Efficiency (at 50% of rated load) | ≥91% |
Residual ripple | ≤80mVpp |
Turn-On delay after applying mains volrage | 1,0s (max) |
Start-up with strong load (capacitive load) | Yes (unlimited) |
Dissipatio load power max | 54W |
Short-circuit protection | Yes |
Overload protection | Yes |
Overvoltage output protection | Yes (Typ. 35V DC) |
Overheating thermal protection | Yes |
BATTERY OUTPUT | |
Boost charge (at In, 25 0C) | 57,6V DC |
Max. Time Boost-Bulk charge (typ. at IN) | 15h |
Min. Time Boost-Bulk charge (typ. at IN) | 1min. |
Float charge (at In, 25 0C) | 55V DC |
Jumper configuration battery type (V/cell) | 2,23V; 2,25V; 2,27V; 2,30V; NiCd-1,40V; Li-ion-3,45V |
Recovery charge | 2-16V DC |
Charging current max Ibat | 10A ±5% |
Charging current limiting Iadj | 10 - 100% / Ibat |
Reverse battery protection | Yes |
Sulfated battery check | Yes, by jumper |
Short circuit element detection | Yes |
Detection of element in short circuit | Yes |
Quiescent current max. | ≤100mA |
Charging curve automatic IUoUo | 4 stage |
Remote input control (RTCON cable) | Boost/float |
LOAD OUTPUT | |
Output voltage (at In) | 44-57,6V DC (31V DC - NiCd) |
Nominal current Iload | 1,1 x In ±5% A DC |
Continuos current (without battery) Iload = In | 10A |
Continuos current (with battery) Iload = In + Ibat | 20A |
Max. current Output Load (Main) Iload (4sec.) | 30A |
Max. current Output Load (Back Up) Iload (4sec.) | 20A |
Start From Battery Without Main (Remote Input Control) | No |
Time Buffering; min (switch output off without main input) | ∞ standard; 5 min.: Require SW |
Threshold alarm Battery almost flat | 40 – 42 Vdc batt |
LVD. (Protections against total Battery discharge) | 38 – 40 Vdc batt |
If connected inparallel with the same product | Double power |
Parallel Load Output | |
Nominal current Iload | 1,1 x 2 x In ±5% A DC |
Continuous current (Without battery) Iload = In | 10A + 10A |
Max. continuous current (With battery) Iload = In + Ibat | 20A + 20A |
Max. current Output Load (Main) Iload (4sec.) | 60A |
Max. current Output Load (Back Up) Iload (4sec.) | 40A |
CLIMATIC DATA | |
Ambient temperature (operation) | -25 ÷ +70°C |
De Rating Ta > 50°C | - 2.5%(In) / °C |
Ambient temperature Storage | -40 ÷ +85°C |
Humidity at 25 °C no condensation | 95% to 25°C |
Altitude: 0 to 2 000m - 0 to 6 560ft | No restrictions |
Altitude: 2 000 to 6 000m - 6 560 to 20 000 ft | De-rating 5°C/1000m |
Cooling | Auto convention |
GENERAL DATA | |
Insulation voltage (IN/OUT) | 3000 Vac |
Insulation voltage (Input / ground) | 1605 Vac |
Insulation voltage (Output / ground) | 500 Vac |
Protection Class (EN/IEC 60529) | IP20 |
Reliability: MTBF IEC 61709 | > 300.000 h |
Pollution Degree Environment | 2 |
Connection Terminal Blocks screw Type | 2,5mm (24–14AWG) |
Protection class (PE Connected) | I, with PE |
Dimensions (w-h-d) | 100x115x135 mm |
Weight | 0,85 kg approx. |
Signal Output (free switch contacts) | |
Main or Backup Input Power | Yes |
Low Battery | Yes |
Fault Battery or system | Yes |
TYPE OF SIGNAL OUTPUT CONTACT | |
Dry Contact. Current can be switched (EN60947.4.1): Max: DC1: 30 Vdc 1 A; AC1: 60 Vac 1A (Resistive load ) Min: 1mA at 5 Vdc (Min permissive load) | |
Fault System / Low Battery | C NC NO |
Main or Back Up | C NC NO |
SIGNAL INPUT / OUTPUT (RJ45) | |
Temp. Comp. Battery (with external probe): Aux Out | RJ Temp AUX1 |
Remote monitoring data | RJ45, Aux2 – Aux3; Modbus RTU |
For more information, please, visit manufacturers website: https://www.adelsystem.com/en/products/uninterruptible-power-supply-output-dc-cbi/datasheet/
Useful information
Specifications
Experimental product description generated by artificial intelligence
DC-UPS All In One 48V 10A - Uninterruptible Power Supply
The ADEL system DC-UPS All In One 48V 10A is a robust and reliable uninterruptible power supply (UPS) designed for security applications. This all-in-one device combines a power supply, battery charger, and backup module into a single, compact unit, simplifying installation and reducing costs.
Key Features
- Parallel connection capability: Enables redundancy for increased system reliability.
- DIN rail mount: Space-saving design ideal for panel mounting.
- 48V 10A output: Provides sufficient power for various security loads.
- Automatic battery diagnostics: Ensures optimal battery performance and longevity.
- Multiple charging stages: Supports various battery types, including Open Lead Acid, Sealed Lead Acid, AGM, Gel Lead Acid, and Ni-Cd.
- Protected against short circuits, overloads, and reverse polarity: Offers enhanced safety and protection.
- Signal outputs: Provides status indication for backup and fault conditions.
Applications
This DC-UPS is ideal for various security applications where reliable power is critical, such as:
- Security systems
- Surveillance cameras
- Access control systems
- Emergency lighting
Why Choose ADEL system DC-UPS?
ADEL system DC-UPS units offer a superior solution for power management in security applications. Their compact design, advanced features, and robust construction ensure reliable operation and long-term performance. The integrated battery management system optimizes battery life and provides early warnings of potential issues. Choose ADEL system for peace of mind and reliable power protection.
Parameter | Value |
---|---|
Brand | ADEL system |
Voltage | 48V |
Current | 10A |
Mounting | DIN rail |
This description is generated using artificial intelligence (AI) and may differ from the actual product. Common AI errors may include:
- Inaccurate product features: some technical specifications, colors, sizes or other parameters may be inaccurate or omitted.
- Incorrect compatibility information: AI may provide incorrect information about the compatibility of products with other devices or systems.
- Overly Optimistic Functions: in some cases functions may be provided whose product iš doesnt really have.
- Name or Model Discrepancies: AI may misrepresent the product name or model.
If you notice inconsistencies or have questions about the description, please contact us before purchasing the product, please contact us by e-mail to you: [email protected].