Control panel and keypad set SECOLINK PAS808+KM20B

Tootekood: CASPAS808KM20B
no gallery
no gallery
Rohkem sarnaseid tooteid

Hinnapiirid

KogusHind KM-ga (tk)
1+
82.21
B2B

Min. kogus: 1

Mitmekordsus: 1

Kokku:

82.21
2024-09-13 Kui tellite praegu on eeldatav kohaletoimetamise kuupäev

Kättetoimetamise tähtajad

2024-09-13 Kui tellite praegu on eeldatav kohaletoimetamise kuupäev

Kaup tellitakse tarnija laost. Kui tarnijal ei ole võimalik tarnida kaupa näidatud kuupäevani, informeerime teid epostitsi.

SaadavalSaadaval

Tarnija ladu

home delivery

Kulleriga koju

Kulleriga koju

Üle 25,00 €

(Tellimused kuni 1000 kgs)

Tasuta

25,00 €-le

(Tellimused kuni 1000 kgs)

4,50 €

Shipping parcel

Kohaletoimetamine DPD pakiautomaatidele

Kohaletoimetamine DPD pakiautomaatidele

Pärast kauba kullerile üleandmist teavitame teid sellest e-posti teel.

3,50 €

Kauba kirjeldus

Control panel and keypad set SECOLINK PAS808+KM20B

Tehnilised andmed

Laokood
U-3816948
NomNr
CASPAS808KM20B

Tarnija toote kirjeldus

  • 8 wired zones on the board
  • 3 PGM outputs
  • 4 areas
  • 5 users
  • Up to 7 keyboards
  • PSTN communicator

Control panel
On-board wired zones8
2-wire smoke detector input-
On-board wireless zones-
Maximum zones in system8
On-board PGM3
Maximum PGM in system8
User + installer codes5+1
Duress codeX1, X2, X3, X4 (when X4 = X4 + 1)
Defaulting user codeYes
Key switch zone-
Partitions4
"Shared" partition (common area)-
System timers-
Maximum keypads/modules in system7
Event log buffer512
PSTN communicatorIn-built
In-built interface for backup communicatorTTL Serial
Data bus protocolKRBUS
Total phone numbers: CMS reporting + personal dialing4
Maximum phone numbers for personal dialingUp to 4
Maximum phone numbers for CMS reportingUp to 4
Reporting protocolContact ID
Voice guide for system control over PSTN-
Voice guide for system programming over PSTN-
"Roller" detector type-
"Vibration" detector typeYes
"Vibration" zone speed (sensitivity)0.01 - 0.25 sec.
Normal zone speed (sensitivity)0.1 - 2.5 sec.
Zone loop (detector) typeNC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration
Arming modeAway, Max Away, Night, Stay.
Zone definitionEntry/exit, entry/exit forced, interior, interior night armed, follower, interior night follower, perimeter, instant, PGM control;
24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature
Zone attributesEnable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm
PGM definitionFire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch
PGM attributesInversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification
Rated voltage of power supply (AC)~20 V
Minimum AC voltage
(note: ~16 V input voltage lets control panel to generate max 0.7 A output current)
~16 V
Maximum AC voltage
(Note: higher than ~22 V voltage can damage control panel)
~22 V
Maximum long term output current of control panel (I+AUX + I+BELL + I+PGM + battery charge):≤1.2 A
Maximum current of slow blowing fuse used in primary AC250 mA
Maximum AC power consumption150 mA
Minimum voltage on +AUX, +BELL, +PGM outputs12 V
Maximum voltage on +AUX, +BELL, +PGM outputs13.9 V
Maximum current out of +AUX+0.8 A
Maximum current out of +BELL+0.8 A
Maximum current into -PGM-0.05 A
Maximum current out of +PGM+0.8 A
Short circuit, overload protection of +BELL, +PGM, +AUXElectronic
Battery charge, +BELL, +AUX current measurement-
Failed (waste) backup battery disconnection-
Maximum battery charging current+0.4 A
Maximum current of fast blowing fuse used in battery circuit3.15 A
Control panel disconnect battery when it’s voltage less than9.5 V
Recommended backup battery12 V, 7 Ah / 20 Hr
Operational compliance+EN50131, Grade2
Overall dimensions W x H in mm145 x 77
Environmental complianceROHS
Operating temperature-10oC up to +50oC
Production statusIn production
Latest firmware versionv0.03
In-field firmware upgrade (by USB)-
Keypad
On-Board zones2
On-Board PGM-
Ambient temperature measurement-
LCD type2 rows 16 symbols each
Keys in keypad20
Programmable fast keys (F-Keys)32
Data bus protocolKRBUS
Zone loop (detector) typeNC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL
Maximum wiring distance to CP300 m
Power supply9 - 14 V
Voltage measurement on keypadYes
Current consumptionBacklight on 100 mA, Baclight off < 50 mA.
On-Board sounderBuzzer
Backlight color Display = blue, keypad = yellow
Character setLatin, Russian, Greek, East European, West European, Azeri, Turkish, Scandinavian.
User interface typeAdvanced, Simple, Baltic, Asian.
Overall dimensions W x H in mm115 x 95
Environmental complianceROHS
Operating temperature0oC up to +50oC
Interface for keypad settings programmingUSB
Interface for keypad firmware updatingUSB

Tarnija toote parameetrid

Product code
CASPAS808KM20B
Category
Control Panels
Supplier's product code
CASPAS808KM20B
Product ID
U-3816948
The information that supplier provides may differ from the actual product. If you noticed an error please let us know by email: [email protected].